Magnetostrictive Displacement Sensor on Industrial Ethernet: PROFINET vs EtherCAT

PROFINET is controller and device, EtherCAT is master and slave; the first question is which master the PLC already carries. For position feedback on industrial Ethernet, Germanjet includes two types: 199PROFINET and 197 / 198 EtherCAT. The roles differ: PROFINET is controller and device; EtherCAT is master and slave. The first test is still whether the PLC has that master. See which fieldbus does my PLC support.

PROFINET and EtherCAT topology compared for displacement sensor position feedback
PROFINET line with switches versus EtherCAT daisy chain

PROFINET (199) — advantages

  • The on-board PN port on Siemens S7-1200 / S7-1500 is the controller, so a new line is cheap to join.
  • Switches are allowed, which keeps cabinet wiring and later extra stations more flexible than a pure daisy chain.
  • IRT can align multi-axis sample times on Siemens motion or hydraulic synchronisation.
  • Diagnostics, device names and topology detection help when a unit is swapped.
  • Configuration uses GSDML, the same habit as TIA Portal.

PROFINET — disadvantages

  • An RJ45 on the CPU is not a PROFINET real-time master. Many ports are only for program download and ordinary TCP.
  • A non-Siemens controller needs a master card or licence; that is not always cheaper than choosing EtherCAT on a master you already have.
  • In IRT the topology is locked; a cable change must be reflected in the project.
  • The shortest scan is usually longer than EtherCAT processing-on-the-fly — enough for most cylinder loops, but check the master on very short motion cycles.

Configuration and device names: 199PROFINET explained, IRT and device names.

EtherCAT (197 / 198) — advantages

  • The Ethernet frame walks the slaves and is read/written on the fly; cycle time follows data volume, not “one frame per station”.
  • DC distributed clocks align sample instants across axes, cleaner than a polling bus.
  • Slaves forward frames, so the sensor segment usually does not need its own switch.
  • No terminating resistor; leave the last slave OUT open.
  • 198 is a single M12 — one less port when nodes are dense.

EtherCAT — disadvantages

  • You need an EtherCAT master (motion controller, IPC master, or a licensed soft PLC). A Siemens on-board PN port is not an EtherCAT master.
  • IN → OUT order is mandatory; a reversal shows up as a wrong sequence or a stuck Init.
  • A bus cycle shorter than the sensor update rate only rereads the same position. Update rate follows stroke; see refresh rate and control cycle.
  • Connectors are often M12 D-coded; do not mix with analogue A-coded or SSI D70. See matching the connector.

Slave and DC: 197, 198, DC and jitter.

Side by side

PROFINET (199)EtherCAT (197/198)
RolesController ↔ deviceMaster ↔ slave
Typical masterS7-1200 / 1500Motion controller / IPC
SynchronisationIRTDC
TopologySwitch or lineIN/OUT daisy chain
Description fileGSDMLESI (XML)
Terminating resistorNot requiredNot required
First choice whenNew Siemens lineFast multi-axis sync

An RJ45 on the CPU is not automatically a PROFINET real-time master or an EtherCAT master; confirm it before ordering 199 or 197. Four-bus table: comparing the whole fieldbus range. Output types: output signals compared.

Frequently Asked Questions

Q: Does a network port on the PLC mean I can buy 199 or 197?

Not from the RJ45 alone. Confirm a PROFINET controller or an EtherCAT master. Many ports are only for programming and ordinary TCP.

Q: Does EtherCAT still need a switch?

The sensor segment is usually IN/OUT daisy-chained; you do not add a switch per rod. PROFINET more often uses switches.

Q: How do 197 and 198 differ?

Both are EtherCAT. 198 is a single M12; 197 is two-port daisy-chain. Protocol and DC are the same family; the difference is the connector and space.

Q: On a new Siemens line, should I still look at EtherCAT?

If the master is S7-1200/1500, choose 199. If the master is already an EtherCAT motion controller, do not add a PROFINET gateway just to stay in a Siemens habit.